To check the accuracy of line laser level
To check the accuracy of line laser level (slope of plane)
Set up the instrument between two walls, the distance is 5
m.Turn on the Cross Line Laser and mark the point of cross
laser line on the wall.
Set up the instrument 0,5-0,7m away from the wall and make, as
described above, the same masrks. If the difference {a1-b2} and
{b1-b2} is less then the value of “accuracy” (see spesications),
there is no need in calibration.
Example: when you check the accuracy of Cross Line Laser the
difference is {a1-a2}=5 mm and {b1-b2}=7 mm. The
instrument’s error: {b1-b2}-{a1-a2}=7-5=2 mm. Now you can
compare this error with standard error.
If the accuracy of Cross Line Laser isn’t corresponding with
claimed accuracy, contact the authorized service center.